• Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Menu
Nexen Engineering Services
Click to enlarge
Home Fire Fighting Passive Fire Protection Louver Panels Louver Panels
Access Panel Door
Back to products
Fire Rated Vision Panel and Fully Glazed door

Louver Panels

ADVANTAGES

Louver provides free passages of air and sufficient light. It provides protection against excessive daylight and glare inside buildings without in any way affecting ventilation to create maximum air flow in and out.

Compare
Add to wishlist
Categories: Fire Fighting, Louver Panels, Passive Fire Protection
Share:
  • Description
  • Reviews (0)
Description

Description

SIZE

To be maximum 24″ x 24″ with fusible link only at the lower portion of the doors.

APPLICATION

Allowed to be used in fire rated honeycomb infill and rockwool infill (maximum density – 80 kg/m3)

Fire Rated Steel Louver should be installed below 1000 mm height from the floor level in the bottom half of the door leaf, minimum distance of the louver cut out from the door edges / as per our approval

Louver cut out – 1.5 mm thick galvanized steel C- Channel should be used around the steel louver for the reinforcement.

Louver Frame and Beading – 1.2 mm Galvanized Steel

Frame is welded to the door leaf and beading is fixed using M4 x 12 mm self- tapping screws, 3 nos. on each sides.

Louver blade – 1.2 mm thick galvanized steel blades are used.

FIRE RATINGS

BRISTOL fire rated louver with fusible link have qualified for the following ratings according to BS 475 part 22 standard.

Integrity up to 240 Minutes

ANSI /UL10C – Up to 90 Minutes

Approval Standard Infill Door Range Leaf Height (mm) Leaf width (mm) Max Area (sq.m) Louver Height Louver width Max Area (sq.m) Fire Rating (Min)
Intertek BS 476-Part 22: 1987 Honey comb Double From 2642 872 2.3 616 616 0.379 30/60/90/120
To 2110 1092
Intertek BS 476-Part 22: 1987 Honey comb Double From 2438 875 2.3 616 616 0.379 180
To 2117 1008
Intertek BS 476-Part 22: 1987 Honey comb Double Max 2032 840 2.3 616 616 0.379 240
Intertek BS 476-Part 22: 1987 Honey comb Single From 2642 918 2.425 616 616 0.379 30/60/90/120
To 2110 1149
Intertek BS 476-Part 22: 1987 Honey comb Single From 2438 921 2.425 616 616 0.379 180
To 2117 1060
Intertek BS 476-Part 22: 1987 Honey comb Single Max 2032 884 1.796 616 616 0.379 240
Intertek BS 476-Part 22: 1987 Rockwool Double From 2337 877 2.07 616 616 0.379 30/60/90/120
To 2120 966
Intertek BS 476-Part 22: 1987 Rockwool Double Max 2032 840 1.7 616 616 0.379 160
Q-MARK BS 476-Part 22: 1987 Honey comb Single From 2456 991 2.433 616 616 0.379 120
To 2230 1092
Q-MARK BS 476-Part 22: 1987 Honey comb Double door From 2456 991 2.433 616 616 0.379 120
To 2230 1092
Q-MARK BS 476-Part 22: 1987 Rockwool Single door From 2438 1092 2.662 616 616 0.379 90
To 2686 991
Q-MARK BS 476-Part 22: 1987 Rockwool Double door From 2438 1092 2.662 616 616 0.379 120
To 2686 991
UL UL 10C Honey comb Single door Max 2136 1040 2.22 616 616 0.379 90
UL UL 10C Honey comb Double Max 2136 1040 2.22 616 616 0.379 90
UL UL 10C Rockwool Double Max 2945 1340 3.946 616 616 0.379 90
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Louver Panels” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Intelligent Heat Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7402 Compliance EN54-5 :2000 +A1:2002 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing T&A,
Add to wishlist
Read more
Quick view
Compare

Addressable Sounder Strobe

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL AVI-6401 Standard EN54-3:2001+A1:2002 + A2:2006 Input Voltage Loop Power: 24VDC [18V to 27.5V] External PSU: 24 VDC [20V to
Add to wishlist
Read more
Quick view
Compare

EFS / PFS (HFC227ea System)

Fire Protection System, Clean Agent System, Fire Fighting
RATIO FLOW CONTROLLER SYSTEM MODEL EFS PFS Design Standard UL 2166 / NFPA 2001 Extinguishing Agent HFC227ea Storage Pressure 360psi
Add to wishlist
Read more
Quick view
Compare

Intelligent Smoke Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7401 Standard EN54-7 :2000 +A1:2002 +A2:2006 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing
Add to wishlist
Read more
Quick view
Compare

Handheld Programmer

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL 7096-0400 Battery Required 2X1.5 AA / Included Current Consumption Standby 0μA, In-use: 3mA Protocol T&A Material / Color ABS
Add to wishlist
Read more
Quick view
Compare

Manual Call Point

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL B61-5101 Standard EN 54-11 Operating Voltage 12VDC ~ 28VDC Standby Current ≤0.5mA Alarm Current ≤20mA (equivalent resistance is 470 /
Add to wishlist
Read more
Quick view
Compare

Test & Drain Valve

Fire Fighting, Fire Protection System, Sprinkler System
NES Test & Drain Valve
Add to wishlist
Read more
Quick view
Compare

Alarm Bell

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL Series BF-AB-0418 Standard BS EN 54-3 Voltage 24VDC Current 25mA Sound Output 93dB @ 1m Movement Motor, Pinion and
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account