• Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Menu
Nexen Engineering Services
Click to enlarge
Home Fire Fighting Fire Detection & Alarm System Addressable FDAS (ADX series) Intelligent Addressable Fire Alarm Control Panel
Power Supply Unit
Back to products
Network LCD Annunciator

Intelligent Addressable Fire Alarm Control Panel

Compare
Add to wishlist
Categories: Addressable FDAS (ADX series), Fire Detection & Alarm System, Fire Fighting
Share:
  • Description
  • Reviews (0)
Description

Description

MODEL Series ADX-2NR/4NR
Standard ANSI/UL 864
Primary AC 120VAC @ 2.1 Amps 60hz or 220VAC @ 1.1Amps 50hz
Output DC 24VDC @ 5.25 Amps (4 Amps available for system power)
Power Supply 5.25 Amps integrated
Charger Current 1.5 Amps max.
Dimensions 14.5″ W x 24″ H x 5″ D
Weight 31 lbs. (without batteries)
Weight 31 lbs. (without batteries)
Color Red (optional gray)
Color Red (optional gray)
Material ABS/steel enclosure
Display 8 line x 40 character LCD (320 characters total)
Network Dual RS485 ports (64 panels max.)
Zones 500 network wide software zones per system
SLC loops 2 or 4 (class A, “style 6 or 7” or class B, “style 4”)
Devices per loop 127 sensors & modules, plus 127 analog sounder bases, 254 total
Addresses per panel (800 addresses + sub-addresses max. per panel)
NAC Outputs 4) 2.5 Amps @ 24VDC (class B)
Relay Outputs (5) Form C 1 Amp @ 30VDC
Voltage Outputs (3) 500mA @ 24VDC
Aux. Power 500mA @ 24VDC
Aux. Inputs (8) digital pull downs
PC Port / Printer RS232
Operating Temp. 32°F (0°C) 120°F (49°C)
Relative Humidity 85% RH Non-Condensing
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Intelligent Addressable Fire Alarm Control Panel” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Alarm Bell

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL Series BF-AB-0418 Standard BS EN 54-3 Voltage 24VDC Current 25mA Sound Output 93dB @ 1m Movement Motor, Pinion and
Add to wishlist
Read more
Quick view
Compare

Multi-sensor

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL BF-SH-0115-2 BF-SH-0115-3 BF-SH-0115-4 Wiring Configuration 2-Wire 3-Wire with Remote Indicator Output 4-Wire with Relay Output Standard EN 54-5 /
Add to wishlist
Read more
Quick view
Compare

Intelligent Multi-sensor

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7403 Compliance EN54-29 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing T&A, Value range
Add to wishlist
Read more
Quick view
Compare

Beam Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-C7404 Compliance EN54-12:2002 Operating Voltage 20 V to 28 V DC Current Parameters Standby:23mA Commission:56mA Alarm:33mA Beam Sensor Sensitivity
Add to wishlist
Read more
Quick view
Compare

Manual Call Point

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-8401 Compliance EN 54-11:2001 + A1:2005 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 1.8mA Protocol/Addressing
Add to wishlist
Read more
Quick view
Compare

Input/Output Module

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IM-8412 Standard EN54-18:2005 Input Voltage Loop Power:24VDC [16V to 28V]; External PSU: 20 to 28VDC Current Consumption Standby 0.6mA,
Add to wishlist
Read more
Quick view
Compare

Heat Detector

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL B61-2001 Standard EN 54-5 Operating Voltage 9VDC ~ 28VDC Quiescent Current ≤60uA Alarm Current 10mA ≤I ≤ 50mA LED indicator
Add to wishlist
Read more
Quick view
Compare

Addressable Sounder Strobe

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL AVI-6401 Standard EN54-3:2001+A1:2002 + A2:2006 Input Voltage Loop Power: 24VDC [18V to 27.5V] External PSU: 24 VDC [20V to
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account