• Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Menu
Nexen Engineering Services
Click to enlarge
Home Fire Fighting Passive Fire Protection Access Panel Door Access Panel Door
Glazed Doors
Glazed Doors
Back to products
Louver Panels
Louver Panels

Access Panel Door

ADVANTAGES

  1. Access control panels are the best option for businesses and industrial buildings.
  2. The use of Access panels is now a good option compared to the standard or engineering doors
  3. The access doors can be used in areas that require high security
Compare
Add to wishlist
Categories: Access Panel Door, Fire Fighting, Passive Fire Protection
Share:
  • Description
  • Reviews (0)
Description

Description

APPLICATION

Four side metal doors flush with a wall surface which provides a closure over a valve or other operable device which is recessed into the wall.

The Access Panel frame is intended to be used in steel stiffened and honeycomb type doors.

The Access Panel frame should use with 0.8 to 1.5 mm Galvanized sheet as per the approvals.

The Access Panel is welded from as per the Approval for the fire door.

CERTIFIED APPROVAL

BS 476 part 22 standards

Integrity up to 240 minutes

Approval Standard Infill Door Range Leaf Height (mm) Leaf width (mm) Max Area (sq.m) Fire Rating (Min)
Intertek BS 476-Part 22: 1987 Honey comb Double From 2642 872 2.3 30/60/90/120
To 2110 1092
Intertek BS 476-Part 22: 1987 Honey comb Double From 2438 875 2.3 180
To 2117 1008
Intertek BS 476-Part 22: 1987 Honey comb Double Max 2032 840 1.706 240
Intertek BS 476-Part 22: 1987 Honey comb Single From 2642 918 2.425 30/60/90/120
To 2110 1149
Intertek BS 476-Part 22: 1987 Honey comb Single From 2438 921 2.425 180
To 2117 1060
Intertek BS 476-Part 22: 1987 Honey comb Single Max 2032 884 1.796 240
Intertek BS 476-Part 22: 1987 Rockwool Double From 2337 877 2.049 30/60/90/120
To 2120 966
Intertek BS 476-Part 22: 1987 Rockwool Double Max 2032 840 1.706 160
Q-MARK BS 476-Part 22: 1987 Honey comb Single From 2456 991 2.433 120
To 2230 1092
Q-MARK BS 476-Part 22: 1987 Honey comb Double door From 2456 991 2.433 120
To 2230 1092
Q-MARK BS 476-Part 22: 1987 Rockwool Single door From 2438 1092 2.662 90
To 2686 991
Q-MARK BS 476-Part 22: 1987 Rockwool Double door From 2438 1092 2.662 120
To 2686 991
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Access Panel Door” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Sprinkler Heads

Fire Fighting, Fire Protection System, Sprinkler System
NES Sprinkler Heads
Add to wishlist
Read more
Quick view
Compare

Intelligent Heat Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7402 Compliance EN54-5 :2000 +A1:2002 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing T&A,
Add to wishlist
Read more
Quick view
Compare

Test & Drain Valve

Fire Fighting, Fire Protection System, Sprinkler System
NES Test & Drain Valve
Add to wishlist
Read more
Quick view
Compare

Sprinkler Head

Fire Fighting, Fire Protection System, Sprinkler System
NES Sprinkler Head
Add to wishlist
Read more
Quick view
Compare

Addressable Sounder Strobe

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL AVI-6401 Standard EN54-3:2001+A1:2002 + A2:2006 Input Voltage Loop Power: 24VDC [18V to 27.5V] External PSU: 24 VDC [20V to
Add to wishlist
Read more
Quick view
Compare

Alarm Bell

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL Series BF-AB-0418 Standard BS EN 54-3 Voltage 24VDC Current 25mA Sound Output 93dB @ 1m Movement Motor, Pinion and
Add to wishlist
Read more
Quick view
Compare

ATUM227 (HFC227ea System)

Fire Protection System, Clean Agent System, Fire Fighting
SYSTEM MODEL ATUM227 Design Standard BS EN 15004-1 / NFPA 2001 Extinguishing Agent HFC227ea Propellant Nitrogen Super-pressurization Storage Pressure 360psi
Add to wishlist
Read more
Quick view
Compare

Bladder Tank & Proportioner

Fire Fighting, Fire Protection System, Foam System
RATIO FLOW CONTROLLER MODEL BBT-RFC2 BBT-RFC3 BBT-RFC4 BBT-RFC6 BBT-RFC8 Nominal Diameter DN50 DN80 DN100 DN150 DN200 Foam Concentrate Inlet Diameter
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account