• Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Menu
Nexen Engineering Services
Click to enlarge
Home Fire Fighting Passive Fire Protection Vision Panel Fire Rated Vision Panel and Fully Glazed door
Louver Panels
Back to products
NES1000 Series Freight Elevator

Fire Rated Vision Panel and Fully Glazed door

ADVANTAGES

  1. Vision Panels are option to view, to allow peoples entering and exiting to see the other side of the door.
  2. Reducing the potential to hit by swinging the door, Vision panes are a way of bringing borrowed light into inner spaces and creating a sense of openness. Vision panels are advanced to use to avoid space in sidelights, transoms or other glazing options.
Compare
Add to wishlist
Categories: Fire Fighting, Passive Fire Protection, Vision Panel
Share:
  • Description
  • Reviews (0)
Description

Description

SIZE

BS 476 part 22 to be Maximum 759 X 428 / 689 X471 (0.324 sq. m)

ANSI/UL10C to be Maximum 250 X 250 (0.0625 sq. m)

DESCRIPTION

The glass light frame is intended to be used in classified hollow metal type; steel stiffened and honeycomb type doors.

Fire Rated Steel Glass Light Frame should be installed above 1100 mm from the floor level

Glass light frame should use with 1 to 1.5 mm Galvanized sheet as per the approvals (BS Standard)

Glass Light Frame is welded from one side on the door and for the other side as follows

ANSI/UL10C

a. Mechanical Interlocking

b. Screw fixing (M5 X 40 mm minimum)

BS 476 Part 22

a. Screw fixing (M5 X 40 mm minimum)

FIRE RATINGS

Bristol Glass light frames have qualified for the following ratings

According to BS 476 part 22 standards Integrity up to 240 minutes.

ANSI/UL10C- Up to 120 minutes

Approval Standard Infill Door Range Leaf Height (mm) Leaf width (mm) Max Area (sq.m) Glazing Height Glazing width Max Area (sq.m) Fire Rating (Min)
Intertek BS 476-Part 22: 1987 Honey comb Double From 2642 872 2.3 759 428 0.324 30/60/90/120
To 2110 1092 689 471
Intertek BS 476-Part 22: 1987 Honey comb Double From 2438 875 2.3 759 410 0.324 180
To 2117 1008 689 428
Intertek BS 476-Part 22: 1987 Honey comb Double Max 2032 840 2.3 660 471 0.27 240
Intertek BS 476-Part 22: 1987 Honey comb Single From 2642 918 2.425 759 428 0.324 30/60/90/120
To 2110 1149 689 471
Intertek BS 476-Part 22: 1987 Honey comb Single From 2438 921 2.425 759 410 0.324 180
To 2117 1060 689 428
Intertek BS 476-Part 22: 1987 Honey comb Single Max 2032 884 1.796 660 471 0.27 240
Intertek BS 476-Part 22: 1987 Rockwool Double From 2337 877 2.07 644 428 0.275 30/60/90/120
To 2120 966 584 471
Intertek BS 476-Part 22: 1987 Rockwool Double Max 2032 840 1.7 560 410 0.23 160
Q-MARK BS 476-Part 22: 1987 Honey comb Single From 2456 991 2.433 626 517 0.323 120
To 2230 1092 690 469
Q-MARK BS 476-Part 22: 1987 Honey comb Double door From 2456 991 2.433 626 517 0.323 120
To 2230 1092 690 469
Q-MARK BS 476-Part 22: 1987 Rockwool Single door From 2438 1092 2.662 632 417 0.262 90
To 2686 991 574 460
Q-MARK BS 476-Part 22: 1987 Rockwool Double door From 2438 1092 2.662 632 417 0.262 120
To 2686 991 574 460
UL UL 10C Honey comb Single door Max 2136 1040 2.22 250 250 0.0625 120
UL UL 10C Honey comb Double Max 2136 1040 2.22 250 250 0.0625 120
UL UL 10C Rockwool Double Max 2945 1340 3.946 250 250 0.0625 90
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Fire Rated Vision Panel and Fully Glazed door” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Power Supply Unit

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL 7096-0500 Standard EN 54-4 Power Supply Mains: AC220V(110-240V),50/60Hz, <130W Backup 24VDC/12Ah sealed lead-acid battery (Not included) Output Power 120W
Add to wishlist
Read more
Quick view
Compare

Short-Circuit Isolator Module

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IM-8414 Standard EN54-17:2005 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.15mA, Alarm: 1.8Ma Maximum Open Voltage (V SO
Add to wishlist
Read more
Quick view
Compare

Sounder Strobe

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL B61-6301 Standard EN 54-3 Operating Voltage 20VDC ~ 28VDC Alarm Current ≤35mA Flashing Frequency 1.4 x (1± 20%) Hz Ingress
Add to wishlist
Read more
Quick view
Compare

Intelligent Smoke Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7401 Standard EN54-7 :2000 +A1:2002 +A2:2006 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing
Add to wishlist
Read more
Quick view
Compare

Manual Call Point

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-8401 Compliance EN 54-11:2001 + A1:2005 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 1.8mA Protocol/Addressing
Add to wishlist
Read more
Quick view
Compare

Alarm Valve

Fire Fighting, Fire Protection System, Sprinkler System
NES Alarm Valve
Add to wishlist
Read more
Quick view
Compare

Addressable Sounder Strobe

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL AVI-6401 Standard EN54-3:2001+A1:2002 + A2:2006 Input Voltage Loop Power: 24VDC [18V to 27.5V] External PSU: 24 VDC [20V to
Add to wishlist
Read more
Quick view
Compare

Test & Drain Valve

Fire Fighting, Fire Protection System, Sprinkler System
NES Test & Drain Valve
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account