Nexen Engineering Services
Click to enlarge
Home Fire Fighting Passive Fire Protection Access Panel Door Access Panel Door
Glazed Doors
Back to products
Louver Panels

Access Panel Door

ADVANTAGES

  1. Access control panels are the best option for businesses and industrial buildings.
  2. The use of Access panels is now a good option compared to the standard or engineering doors
  3. The access doors can be used in areas that require high security
Compare
Add to wishlist
Categories: Access Panel Door, Fire Fighting, Passive Fire Protection
Share:
  • Description
  • Reviews (0)
Description

Description

APPLICATION

Four side metal doors flush with a wall surface which provides a closure over a valve or other operable device which is recessed into the wall.

The Access Panel frame is intended to be used in steel stiffened and honeycomb type doors.

The Access Panel frame should use with 0.8 to 1.5 mm Galvanized sheet as per the approvals.

The Access Panel is welded from as per the Approval for the fire door.

CERTIFIED APPROVAL

BS 476 part 22 standards

Integrity up to 240 minutes

Approval Standard Infill Door Range Leaf Height (mm) Leaf width (mm) Max Area (sq.m) Fire Rating (Min)
Intertek BS 476-Part 22: 1987 Honey comb Double From 2642 872 2.3 30/60/90/120
To 2110 1092
Intertek BS 476-Part 22: 1987 Honey comb Double From 2438 875 2.3 180
To 2117 1008
Intertek BS 476-Part 22: 1987 Honey comb Double Max 2032 840 1.706 240
Intertek BS 476-Part 22: 1987 Honey comb Single From 2642 918 2.425 30/60/90/120
To 2110 1149
Intertek BS 476-Part 22: 1987 Honey comb Single From 2438 921 2.425 180
To 2117 1060
Intertek BS 476-Part 22: 1987 Honey comb Single Max 2032 884 1.796 240
Intertek BS 476-Part 22: 1987 Rockwool Double From 2337 877 2.049 30/60/90/120
To 2120 966
Intertek BS 476-Part 22: 1987 Rockwool Double Max 2032 840 1.706 160
Q-MARK BS 476-Part 22: 1987 Honey comb Single From 2456 991 2.433 120
To 2230 1092
Q-MARK BS 476-Part 22: 1987 Honey comb Double door From 2456 991 2.433 120
To 2230 1092
Q-MARK BS 476-Part 22: 1987 Rockwool Single door From 2438 1092 2.662 90
To 2686 991
Q-MARK BS 476-Part 22: 1987 Rockwool Double door From 2438 1092 2.662 120
To 2686 991
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Access Panel Door” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Input/Output Module

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IM-8412 Standard EN54-18:2005 Input Voltage Loop Power:24VDC [16V to 28V]; External PSU: 20 to 28VDC Current Consumption Standby 0.6mA,
Add to wishlist
Read more
Quick view
Compare

Sprinkler Head

Fire Fighting, Fire Protection System, Sprinkler System
NES Sprinkler Head
Add to wishlist
Read more
Quick view
Compare

Short-Circuit Isolator Module

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IM-8414 Standard EN54-17:2005 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.15mA, Alarm: 1.8Ma Maximum Open Voltage (V SO
Add to wishlist
Read more
Quick view
Compare

EFS / PFS (HFC227ea System)

Fire Protection System, Clean Agent System, Fire Fighting
RATIO FLOW CONTROLLER SYSTEM MODEL EFS PFS Design Standard UL 2166 / NFPA 2001 Extinguishing Agent HFC227ea Storage Pressure 360psi
Add to wishlist
Read more
Quick view
Compare

Sprinkler Heads

Fire Fighting, Fire Protection System, Sprinkler System
NES Sprinkler Heads
Add to wishlist
Read more
Quick view
Compare

Intelligent Heat Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7402 Compliance EN54-5 :2000 +A1:2002 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing T&A,
Add to wishlist
Read more
Quick view
Compare

Beam Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-C7404 Compliance EN54-12:2002 Operating Voltage 20 V to 28 V DC Current Parameters Standby:23mA Commission:56mA Alarm:33mA Beam Sensor Sensitivity
Add to wishlist
Read more
Quick view
Compare

Sounder Strobe

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL B61-6301 Standard EN 54-3 Operating Voltage 20VDC ~ 28VDC Alarm Current ≤35mA Flashing Frequency 1.4 x (1± 20%) Hz Ingress
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account