Click to enlarge
Home Fire Fighting Fire Pumps Accessories Fuel Tank Fuel Tank
Waste Cone
Back to products
Honeycomb Core

Fuel Tank

FEATURES

– UL-142 Label
– Standard Capacity: 25 – 360 Gallons
– Thickness of 10mm MS Steel
– Flat flanged heads in single wall configurations
– Connections for normal and emergency venting, gauging, filling and product piping
– Lifting lugs
– Structural legs for easy installation
– Primer paint, Red spray paint finished

Compare
Add to wishlist
Categories: Accessories, Fire Fighting, Fire Pumps, Fuel Tank
Share:
  • Description
  • Reviews (0)
Description

Description

NES Aboveground are primarily designed for safe storage of flammable and combustible liquids. These tanks are designed, fabricated, tested and labeled in accordance with Underwriters Laboratories, Inc. UL-142 (Steel Aboveground Tanks for Flammable and Combustible Liquids) standard. Tanks are designed and engineered to meet the demanding needs of many industries.

We have experienced team that offers quality engineering and support to help you customize your tank to your specific application. Our tanks are produced according to the highest standards for the commercial, industrial, public and private sectors.

CAPACITY

Model CAP
BFE25 25 Gallon
BFE70 70 Gallon
BFE70 70 Gallon
BFE120 120 Gallon
BFE180 180 Gallon
BFE280 280 Gallon
BFE360 360 Gallon
  1. Tank Shell
  2. End Cap (Dished Head)
  3. Leg Assembly
  4. Filler Neck
  5. Fill Cap with Provisions for Pad-Lock with Removable Strainer (1/16″ Mesh)
  6. Emergency Vent
  7. Normal Vent (2″)
  8. Fuel Level Indicator Gauge Connection (2″)
  9. NPT Connection for Fuel Switch
  10. Return Connection (1″)
  11. Discharge Connection (1 1/4″)
  12. Drain Connection
Model Tank Capacity Dimension in Inches Approx Weight
Length Width Height
BFE25 25 32.71 16 39.3 57
BFE70 70 46.96 22 44.7 87
BFE120 120 43.27 30 52.7 108
BFE180 180 63.78 30 52.7 137
BFE280 280 50.87 42 61.6 168
BFE360 360 64.76 42 61.6 195
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Fuel Tank” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Intelligent Addressable Fire Alarm Control Panel

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL Series IGN-250 Standard EN54-2: 1997 + A1: 2006 & EN54-4: 1997 + A1: 2002 + A2: 2006 Maximum Loop
Add to wishlist
Read more
Quick view
Compare

Intelligent Heat Detector

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7402 Compliance EN54-5 :2000 +A1:2002 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing T&A,
Add to wishlist
Read more
Quick view
Compare

EFS / PFS (HFC227ea System)

Fire Protection System, Clean Agent System, Fire Fighting
RATIO FLOW CONTROLLER SYSTEM MODEL EFS PFS Design Standard UL 2166 / NFPA 2001 Extinguishing Agent HFC227ea Storage Pressure 360psi
Add to wishlist
Read more
Quick view
Compare

Input/Output Module

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IM-8412 Standard EN54-18:2005 Input Voltage Loop Power:24VDC [16V to 28V]; External PSU: 20 to 28VDC Current Consumption Standby 0.6mA,
Add to wishlist
Read more
Quick view
Compare

Intelligent Multi-sensor

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL IGN-7403 Compliance EN54-29 Input Voltage 24VDC [16V to 28V] Current Consumption Standby 0.6mA, Alarm: 4mA Protocol/Addressing T&A, Value range
Add to wishlist
Read more
Quick view
Compare

Handheld Programmer

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL 7096-0400 Battery Required 2X1.5 AA / Included Current Consumption Standby 0μA, In-use: 3mA Protocol T&A Material / Color ABS
Add to wishlist
Read more
Quick view
Compare

ATUM227 (HFC227ea System)

Fire Protection System, Clean Agent System, Fire Fighting
SYSTEM MODEL ATUM227 Design Standard BS EN 15004-1 / NFPA 2001 Extinguishing Agent HFC227ea Propellant Nitrogen Super-pressurization Storage Pressure 360psi
Add to wishlist
Read more
Quick view
Compare

Test & Drain Valve

Fire Fighting, Fire Protection System, Sprinkler System
NES Test & Drain Valve
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account