• Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Menu
Nexen Engineering Services
Click to enlarge
Home Fire Fighting Fire Pumps Vertical Turbines Vertical Turbine
Horizontal Split Case
Horizontal Split Case
Back to products
Fire Pump Packages
Fire Pump Packages

Vertical Turbine

FEATURES

– Performance and hydrostatic tests
– In compliance with NFPA 20, UL 448 requirements
– Materials of construction: cast iron, bronze fitted
– Sealing arrangement: packing with flushing
– Modular construction: assures complete flexibility in selecting a pump
– Pre-engineered standard components
– Space-saver design: requires minimum floor space
– Static suction lift: permissible by NFPA 20 where water source is located below ground
– Open line shaft: water-lubricated bowl and line-shaft bearings
– Stuffing Box (Gland) – (Bronze) – to press the packing gland into the seal area through bolts
– Bolted bowl: bowls and suction bell are bolted together, allowing easier disassembly
– Dynamic balanced impellers: secured to the shaft with steel locking collets
– Discharge gauge connection

Compare
Add to wishlist
Categories: Fire Fighting, Fire Pumps, Vertical Turbines
Share:
  • Description
  • Reviews (0)
Description

Description

NES Vertical Turbine centrifugal pump is developed and fabricated by our company, according to NFPA20. This pump is used for any underground water source where the water level is below the pump suction, it’s Impeller remains submerged with the water tank at all times.

Where the fire protection water source is located below ground or deck level, the best technical pumping solution is the vertical suspended multi stage turbine pump. With this type of unit the impellers are fully immersed in the water maintaining prime at all times. The pumps are driven by vertical electric motors or by diesel engines through a right angle gearbox.

PERFORMANCE RANGE

– Capacity  From 500 GPM up to 5000 GPM
– Head  From 50 MTR up to 200 MTR

MATERIALS OF CONSTRUCTION

– Shaft  Stainless Steel
– Casing  Cast Iron
– Impeller  Bronze

CROSS SECTIONAL

VTP Selection Chart

No. Model Capacity (m3 /h) (GPM) UL Listed Pressure (kpa (PSI)) Rated Speed (RPM)
1 BVP 350 45 (200) 1883 (266) 1470
2 BVP 350 45 (200) 868-1860 (126-270) 1770
3 BVP 350 68 (300) 1826 (265) 1470
4 BVP 350 68 (300) 861-1853 (125-269) 1770
5 BVP 350 91 (400) 1791 (260) 1470
6 BVP 350 91 (400) 854-1846 (124-268) 1770
7 BVP 350 115 (500) 1736 (252) 1470
8 BVP 350 115 (500) 840-1812 (122-263) 1770
9 BVP 400 115 (500) 551-1936 (80-281) 1470
10 BVP 400 115 (500) 751-2129 (109-309) 1770
11 BVP 350 170 (750) 1598 (232) 1470
12 BVP 350 170 (750) 799-1695 (116-246) 1770
13 BVP 400 170 (750) 537-1867 (78-271) 1470
14 BVP 400 171 (750) 730-2060 (106-299) 1770
15 BVP 350 227 (1000) 1440 (209) 1470
16 BVP 350 227 (1000) 751-1578 (109-229) 1770
17 BVP 400 227 (1000) 510-1764 (74-256) 1470
18 BVP 400 227 (1000) 710-2005 (103-291) 1770
19 BVP 400 285 (1250) 482-1654 (70-240) 1470
20 BVP 400 285 (1250) 668-1564 (97-227) 1770
21 BVP 400 340 (1500) 455-1550 (66-225) 1470
22 BVP 400 340 (1500) 627-1798 (91-261) 1770
Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Vertical Turbine” Cancel reply

Your email address will not be published. Required fields are marked *

Related products

Compare

Sprinkler Heads

Fire Fighting, Fire Protection System, Sprinkler System
NES Sprinkler Heads
Add to wishlist
Read more
Quick view
Compare

Heat Detector

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL B61-2001 Standard EN 54-5 Operating Voltage 9VDC ~ 28VDC Quiescent Current ≤60uA Alarm Current 10mA ≤I ≤ 50mA LED indicator
Add to wishlist
Read more
Quick view
Compare

Handheld Programmer

Fire Detection & Alarm System, Addressable FDAS, Fire Fighting
MODEL 7096-0400 Battery Required 2X1.5 AA / Included Current Consumption Standby 0μA, In-use: 3mA Protocol T&A Material / Color ABS
Add to wishlist
Read more
Quick view
Compare

Water/Foam Monitor

Fire Fighting, Fire Protection System, Foam System
MODEL Inlet Flange Barrel Flow Rate Induction Mechanism Horizontal Throw @ 30° Still Air Water Foam-Water FFM-SI-500-4 4″ 3″ 500gpm
Add to wishlist
Read more
Quick view
Compare

Smoke Detector

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL B61-1001 Standard EN 54-7 Operating Voltage 9VDC ~ 28VDC Quiescent Current ≤60uA Alarm Current 10mA ≤I ≤ 50mA LED indicator
Add to wishlist
Read more
Quick view
Compare

Bladder Tank & Proportioner

Fire Fighting, Fire Protection System, Foam System
RATIO FLOW CONTROLLER MODEL BBT-RFC2 BBT-RFC3 BBT-RFC4 BBT-RFC6 BBT-RFC8 Nominal Diameter DN50 DN80 DN100 DN150 DN200 Foam Concentrate Inlet Diameter
Add to wishlist
Read more
Quick view
Compare

Multi-sensor

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL BF-SH-0115-2 BF-SH-0115-3 BF-SH-0115-4 Wiring Configuration 2-Wire 3-Wire with Remote Indicator Output 4-Wire with Relay Output Standard EN 54-5 /
Add to wishlist
Read more
Quick view
Compare

Alarm Bell

Fire Detection & Alarm System, Conventional FDAS, Fire Fighting
MODEL Series BF-AB-0418 Standard BS EN 54-3 Voltage 24VDC Current 25mA Sound Output 93dB @ 1m Movement Motor, Pinion and
Add to wishlist
Read more
Quick view
Nexen__1 png
  • Lahore Office: +92-336-481-5555
  • Balochistan Regional Office: 081-2450777
  • inquiry@nespk.com
  • waqar@nespk.com
  • Head Office: Plaza 71-B, 3rd Floor, Broadway Commercial DHA V-III, Lahore
  • Balochistan Regional Office: Office # 10, 3rd floor, Iqbal center Quetta

Help & Support

  • Contact Us
  • About Us

Useful Links

Mobile-alt Envelope
created by 2023 NAVICO ADS. All rights reserved
  • Home
  • Products
    • Air Conditioning
    • Elevators
    • Escalator
    • Moving Walks
    • Fire Fighting
      • Fire Detection & Alarm System
        • Addressable FDAS
        • Addressable FDAS (ADX series)
      • Fire Pumps
        • Accessories
          • Miscellaneous
      • Fire Protection System
      • Fire Protection Valves
  • About us
  • Contact us
Shop
Wishlist
0 items Cart
My account